Shot Flow Control

Supplies

Magnavalves are a standard in the peening industry. They have no moving parts and are very reliable. Please call us to select the best one for your application.

Product: MagnaValves – air type Model No.
MagnaValve, – 20 lbs flow rate, (on/off) (110vac.) 178-AC
MagnaValve, – 20 lbs flow rate, (on/off) (24Vdc.) 178-DC
MagnaValve, – 100 lbs flow rate (on/off) (110Vac) 179-AC
MagnaValve, – 100 lbs flow rate (on/off) (24Vdc) 179-DC
MagnaValve, – 200 lbs flow rate (on/off) (110Vac) 180-AC
MagnaValve, – 200 lbs flow rate (on/off) (24Vdc) 180-DC
MagnaValve, – 300 lbs flow rate (on/off) (110Vac) 190-AC
MagnaValve, – 300 lbs flow rate (on/off) (24Vdc) 190-DC
MagnaValve, 0- 2 lbs flow rate, 0-10 Vdc output , 1″ (24Vdc) 576-24
MagnaValve, 0- 10 lbs flow rate, 0-10 Vdc output , 1″ (24Vdc) 577-24
MagnaValve, 0- 20 lbs flow rate, 0-10 Vdc output, 1 1/4″ (24Vdc) 578-24
MagnaValve, 578-24-GT 578-24 GT
MagnaValve, 0- 20 lbs flow rate, 0-10 Vdc output, 1 1/4″ (24Vdc), RTS 578-24 RTS
MagnaValve, 0- 100 Lbs flow rate, 0-10 Vdc Output , 1 1/4″(24Vdc) 579-24
MagnaValve, 0- 300 Lbs flow rate , 0-10 Vdc Output, 5% accuracy, 2″ (24Vdc) 590-24
MagnaValve, 0- 30 lbs adjustable flow rate, (no internal flow rate sensor) 1 1/4″ 278
MagnaValve, 0- 100 Lbs adjustable flow rate, (no internal flow rate sensor) 1 1/4″ 279
MagnaValve, 0- 200 Lbs adjustable flow rate, (no internal flow rate sensor), 2″ 280
MagnaValve, 0- 20 lbs flow rate, 0-5 Vdc output, 1 1/4″ Frequency Output 378
MagnaValve, 0- 2 lbs flow rate, 0-5 Vdc output,1% Accuracy, 1″ See 1477C 477
MagnaValve, 0- 20 lbs flow rate, 0-5 Vdc output, 1% Accuracy, 1 1/4″ See 1478C 478
MagnaValve, 0- 100 Lbs flow rate, 0-5 Vdc output,1% Accuracy, 1 1/4″ 479
MagnaValve, 0- 300 Lbs flow rate, 0-5 Vdc Output, 1% Accuracy, 2″ 490
MagnaValve, 0- 20 lbs flow rate, 0-5 Vdc output, 1 1/4″ replaces 578C 578
MagnaValve, 0- 100 Lbs flow rate, 0-5 Vdc Output , 1 1/4″ 579
MagnaValve, 0- 200 Lbs flow rate , 0-5 Vdc Output, 5% accuracy, 2″ 580
MagnaValve, 0- 300 Lbs flow rate , 0-5 Vdc Output, 5% accuracy, 2″ 590

Product: MagnaValves – wheel type Model No.
MagnaValve, 0-2000 Lbs flow rate, no internal flow sensor, 3.5″ high 24 Vdc LP-24
MagnaValve, 0-1000 Lbs flow rate, no internal flow sensor, 2.5″ high 24 Vdc VLP-24
Magnavalve, 0-1200 lbs flow rate, with internal sensor, 0-10 Vdc output 500-24
MagnaValve, 0-2200 lbs flow rate, 100Hp Wheel, no internal flow sensor (see LP) 100
MagnaValve, 0- 700 lbs flow rate, 25Hp Wheel,1% flow Accuracy voltage output 250-P
MagnaValve, 0- 700 lbs flow rate, 25Hp Wheel, 5% flow Accuracy voltage output 250-N
MagnaValve, 0-1200 lbs flow rate, 50Hp Wheel, 1% flow Accuracy voltage output 500-P
MagnaValve, 0-1200 lbs flow rate, 50Hp Wheel, 5% flow Accuracy voltage output 500-N
MagnaValve, WM WM
MagnaValve,0-2000 Lbs flow rate, 3.5″ high,0-120Vac adj flow (includes Variac) LP-2000VAR
MagnaValve, 0-2000 Lbs flow rate, no internal flow sensor, 3.5″ high LP-2000
MagnaValve, 0-2000 Lbs flow rate, no internal flow sensor, 3.5″ high off/on version LP-0/1
MagnaValve, 0-1000 Lbs flow rate, 2.5″ high 0-120Vac adj flow (includes Variac) VLP-1000VAR
MagnaValve, 0-1000 Lbs flow rate, no internal flow sensor, 2.5″ high VLP-1000
MagnaValve, 0-1000 Lbs flow rate, no internal flow sensor, 2.5″ high off/on version VLP-0/1

Product: Controls Model No.
Controller, Motor Amperage, (24Vdc) AC-24
Controller, Shot Flow Rate Lb./min or Kg/min (24Vdc) FC-24
Controller, Motor Amperage, with .050 Ohm current shunt resistor AC
Controller, Shot Flow Rate Lb./min, with +/- 12Vdc excitation outputs FC
Controller, Manual, with set pot and internal transformer MC
Power Pak, Manual, order 48 Vac Transformer and external pot separate 102

Product: Monitors Model No.
Monitor, Media Flow, 10-bar display, 0-5Vdc input, w/high-low alarm output MSD
Monitor, Display, Dual Alarm, for 399 Series Sensors (frequency type)(See MSD) 260-P